Anviz Facial Recognition Calibration
How to calibrate the Anviz facial recognition device
Firstly you will need to print out the A4 calibration page and mount it to something flat. Please download the calibration paper here.
Device calibration improves the facial recognition efficiency of the Facial recognition. Once you have the calibration paper prepared, following the below instructions to calibrate:
Calibrating Anviz facial recognition
- Power on the Anviz terminal
- Click the Cog icon and enter 000012 to activate Lens Calibration mode
- The terminal will then ask if you want to enter Lens Calibration mode. Click Yes(OK)
- The terminal will now restart in lens calibration mode
- After restart, a red box will appear on screen
- Make sure your calibration paper fits inside the red box then adjust accordingly
- You should try to fit the calibration paper within the edges of the red box
- When successful you will notice the red box get smaller
- Repeat the process again within the smaller box
- Once completed Success will appear on screen
- Click Close and the terminal will restart
- Calibration is now complete and you can continue using the terminal again